ARL170R/F250XZ Measurements log periodic antennas 170-250MHz
MONITORING ANTENNAS FOR MOBILE AND STATIONARY USE, PROVIDING COMPLETE COVERAGE RANGE 170 MHz TO 250 MHz
MOD. ARL170R/F250XZ - COD. ARL170R/F250XZ
Measurement - Monitoring Antenna
MOD. ARL170R/F250XZ - COD. ARL170R/F250XZ
Measurement - Monitoring Antenna
Complete manual including:
• Internal calibration with typical gain factor
• Datasheet with general product characteristics
• Certificate of Conformity including the product serial number
• H/V radiation patterns
• Return loss test report
• K-factor calculation
• Assembly instructions
• Internal calibration with typical gain factor
• Datasheet with general product characteristics
• Certificate of Conformity including the product serial number
• H/V radiation patterns
• Return loss test report
• K-factor calculation
• Assembly instructions
ELECTRICAL DATA
Frequency range A MHz 170 ÷ 250
Bandwidth MHz 80
Gain max . dBi 9.5
Return loss dB ≥ -14
VSWR ≤ 1.5:1
Nominal impedance Ω 50
Polarization Ω V/H
H beamwidth 170 Mhz -3 dB 100°
H beamwidth 200 Mhz -3 dB 80°
H beamwidth 230 Mhz -3 dB 90°
E beamwidth 170 Mhz -3 dB 60°
E beamwidth 200 Mhz -3 dB 55°
E beamwidth 230 Mhz -3 dB 50°
Max Power W 200 W
Connector Nf
Lightning protection All metal parts are D.C. grounded
MECHANICAL DATA
Dimension length mm 1225X920x130
Elements numbers 8
Weight without clamp kg 2.9
Wind surface m² Front 0.02 side 0.07
Front wind load Kg 0.7 ( 25 m/s )
Side wind load Kg 2.9 ( 25 m/s )
Mounting +/- 90° mm standard polarizer Ø 30
MATERIALS
Anticorodal alluminium - Brass - Teflon - Polyvinyl chloride - RoHS compliance
ACCESSORIES
SUPIS01 Isolation fiberglass pole Ø 35 x 1000
BAG170250 Transport bag
ORDERING AND PACKAGING INFORMATIONS
ARL170F250XZ With unscrewed elements
ARL170R250XZ With folding elements
PACKAGING mm. 1300x200x200 / weight 4 Kg
Frequency range A MHz 170 ÷ 250
Bandwidth MHz 80
Gain max . dBi 9.5
Return loss dB ≥ -14
VSWR ≤ 1.5:1
Nominal impedance Ω 50
Polarization Ω V/H
H beamwidth 170 Mhz -3 dB 100°
H beamwidth 200 Mhz -3 dB 80°
H beamwidth 230 Mhz -3 dB 90°
E beamwidth 170 Mhz -3 dB 60°
E beamwidth 200 Mhz -3 dB 55°
E beamwidth 230 Mhz -3 dB 50°
Max Power W 200 W
Connector Nf
Lightning protection All metal parts are D.C. grounded
MECHANICAL DATA
Dimension length mm 1225X920x130
Elements numbers 8
Weight without clamp kg 2.9
Wind surface m² Front 0.02 side 0.07
Front wind load Kg 0.7 ( 25 m/s )
Side wind load Kg 2.9 ( 25 m/s )
Mounting +/- 90° mm standard polarizer Ø 30
MATERIALS
Anticorodal alluminium - Brass - Teflon - Polyvinyl chloride - RoHS compliance
ACCESSORIES
SUPIS01 Isolation fiberglass pole Ø 35 x 1000
BAG170250 Transport bag
ORDERING AND PACKAGING INFORMATIONS
ARL170F250XZ With unscrewed elements
ARL170R250XZ With folding elements
PACKAGING mm. 1300x200x200 / weight 4 Kg
Directional antenna for VHF Band III measurement workflows, covering 170–250 MHz.
This spectrum is widely used for DAB/DAB+ broadcasting and (depending on national allocations) for VHF TV services, so typical activities include field-strength surveys,
coverage verification, multiplex/TV audits and troubleshooting unwanted emissions. The directional log-periodic design helps improve selectivity and supports direction indication during interference hunting and RF diagnostics.
The antenna supports both fixed monitoring sites/control centers and mobile operations. For transport and deployment you can choose the most practical supply: ARL170R250XZ with folding elements to reduce bulk during missions, or ARL170F250XZ with unscrewed elements for packing/logistics requirements. V/H polarization supports measurement sessions where you must match or compare polarizations across services and scenarios.
Radiomonitoring
Direction Finding Antennas
RF Signal Search and Survey
Monitoring and measurement of RF signals
Antenna designed and manufactured in Italy.
The antenna supports both fixed monitoring sites/control centers and mobile operations. For transport and deployment you can choose the most practical supply: ARL170R250XZ with folding elements to reduce bulk during missions, or ARL170F250XZ with unscrewed elements for packing/logistics requirements. V/H polarization supports measurement sessions where you must match or compare polarizations across services and scenarios.
Radiomonitoring
Direction Finding Antennas
RF Signal Search and Survey
Monitoring and measurement of RF signals
Antenna designed and manufactured in Italy.
Frequently asked questions about ARL170R/F250XZ
Quick answers for VHF Band III (170–250 MHz) radiomonitoring teams, DAB/VHF TV survey units and fixed monitoring stations.
What is the ARL170R/F250XZ used for?
Directional broadband measurements across 170–250 MHz for radiomonitoring, RF surveys, direction indication and interference hunting, typically for DAB Band III and VHF TV measurement workflows.
Which services fall inside 170–250 MHz?
VHF Band III is commonly used for DAB/DAB+ and (depending on regional allocations) VHF TV. Typical tasks include coverage and field-strength surveys, multiplex/TV audits and troubleshooting unwanted emissions.
Why choose a directional log-periodic antenna for Band III surveys?
Directionality improves selectivity and reduces off-axis pickup, supporting more reliable surveys and helping localization and direction indication during interference troubleshooting.
Folding elements or unscrewed elements: which one should I choose?
Choose ARL170R250XZ with folding elements to reduce bulk during transport, or ARL170F250XZ with unscrewed elements when packing/logistics are the priority.
What does V/H polarization mean in practice?
V/H polarization indicates the antenna can be used in vertical or horizontal polarization, useful when matching the service polarization or comparing both during measurement sessions.
What documentation is included for professional reporting?
A complete manual can include internal calibration with typical gain factor, datasheet, certificate of conformity (with serial number), H/V radiation patterns,
return loss test report, K-factor calculation and assembly instructions.
Related topics and searches
Typical queries and applications related to ARL170R/F250XZ and similar Protel measurement antennas:
log periodic measurement antenna 170-250 MHz DAB Band III monitoring antenna 174-240 VHF TV Band III measurement antenna direction finding antenna VHF Band III interference hunting directional antenna 170-250 field strength survey antenna Band III folding elements log periodic antenna unscrewed elements antenna for transport V/H polarization measurement antenna Nf connector 50 ohm VHF antenna return loss VSWR test report antenna K-factor documentation measurement antennaVISIT "ANTENNAKIT" – BEST QUALITY – LOWER PRICE – CLICK BELOW
https://www.antennaskit.com/